Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage690 - 690V
Rated permanent current Iu250A
Number of poles4
Overload release current setting45.00 - 250A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Degree of protection (IP)IP20
Type of electrical connection of main circuitBolt connection
Type of control elementToggle
Motor drive integratedNo
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Adjustment range short-term delayed short-circuit release150.0 - 2500A
Adjustment range undelayed short-circuit release375.0 - 3000A
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA059480R1 | T4N 250 PR223EF 250 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

690 .. 690V

Rated permanent current Iu

250A

Number of poles

4

Overload release current setting

45.00 .. 250A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Bolt connection

Type of control element

Toggle

Motor drive integrated

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Adjustment range short-term delayed short-circuit release

150.0 .. 2500A

Adjustment range undelayed short-circuit release

375.0 .. 3000A

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Motor drive optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.