  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With under voltage releaseNo
Rated voltage690 - 690V
Overload release current setting57.60 - 320A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Adjustment range short-term delayed short-circuit release192.0 - 3200A
Adjustment range undelayed short-circuit release480.0 - 3840A
Rated permanent current Iu320A
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorNo
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Number of auxiliary contacts as normally open contact0
Complete device with protection unitYes
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Position of connection for main current circuitFront side
Type of control elementToggle
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Number of poles4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA059482R1 | T4L 320 PR223EF 320 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With under voltage release

Rated voltage

690 .. 690V

Overload release current setting

57.60 .. 320A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Adjustment range short-term delayed short-circuit release

192.0 .. 3200A

Adjustment range undelayed short-circuit release

480.0 .. 3840A

Rated permanent current Iu

320A

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

With switched-off indicator

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Number of auxiliary contacts as normally open contact

0

Complete device with protection unit

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Position of connection for main current circuit

Front side

Type of control element

Toggle

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Number of poles

4