Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of poles4
Position of connection for main current circuitFront side
Adjustment range undelayed short-circuit release240.0 - 1920A
Overload release current setting64.0 - 160A
Rated voltage690 - 690V
Number of auxiliary contacts as change-over contact0
Motor drive optionalYes
Type of control elementToggle
Motor drive integratedNo
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Degree of protection (IP)IP20
Rated permanent current Iu250A
Type of electrical connection of main circuitBolt connection
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release96.0 - 1600A
With switched-off indicatorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA059500R1 | T4S 250 PR223DS IN=160 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of poles

4

Position of connection for main current circuit

Front side

Adjustment range undelayed short-circuit release

240.0 .. 1920A

Overload release current setting

64.0 .. 160A

Rated voltage

690 .. 690V

Number of auxiliary contacts as change-over contact

0

Motor drive optional

Type of control element

Toggle

Motor drive integrated

With under voltage release

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Degree of protection (IP)

IP20

Rated permanent current Iu

250A

Type of electrical connection of main circuit

Bolt connection

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

96.0 .. 1600A

With switched-off indicator

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.