Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu400A
Number of poles4
Number of auxiliary contacts as normally open contact0
Overload release current setting128.0 - 320A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Motor drive integratedNo
Position of connection for main current circuitFront side
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Type of control elementToggle
Motor drive optionalYes
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release192.0 - 3200A
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
With under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
DIN rail (top hat rail) mounting optionalNo
Adjustment range undelayed short-circuit release480.0 - 3840A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA059530R1 | T5N 400 PR223DS IN=320 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

400A

Number of poles

4

Number of auxiliary contacts as normally open contact

0

Overload release current setting

128.0 .. 320A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Motor drive integrated

Position of connection for main current circuit

Front side

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Type of control element

Toggle

Motor drive optional

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

192.0 .. 3200A

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

With under voltage release

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

480.0 .. 3840A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.