Technical specifications

With under voltage releaseNo
Rated permanent current Iu630A
Integrated earth fault protectionNo
Overload release current setting252.0 - 630A
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Rated voltage690 - 690V
Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release378.0 - 6300A
Motor drive integratedNo
Number of poles4
Degree of protection (IP)IP20
Motor drive optionalYes
Type of control elementToggle
Complete device with protection unitYes
Adjustment range undelayed short-circuit release945.0 - 5985A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA059534R1 | T5N 630 PR223DS IN=630 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With under voltage release

Rated permanent current Iu

630A

Integrated earth fault protection

Overload release current setting

252.0 .. 630A

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

378.0 .. 6300A

Motor drive integrated

Number of poles

4

Degree of protection (IP)

IP20

Motor drive optional

Type of control element

Toggle

Complete device with protection unit

Adjustment range undelayed short-circuit release

945.0 .. 5985A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.