Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
Overload release current setting252.0 - 630A
Rated permanent current Iu630A
With switched-off indicatorNo
Motor drive integratedNo
Type of control elementToggle
Number of auxiliary contacts as change-over contact0
Number of poles4
Adjustment range undelayed short-circuit release945.0 - 5985A
Adjustment range short-term delayed short-circuit release378.0 - 6300A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Number of auxiliary contacts as normally open contact0
Rated voltage690 - 690V
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Motor drive optionalYes
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA059552R1 | T5L 630 PR223DS IN=630 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

252.0 .. 630A

Rated permanent current Iu

630A

With switched-off indicator

Motor drive integrated

Type of control element

Toggle

Number of auxiliary contacts as change-over contact

0

Number of poles

4

Adjustment range undelayed short-circuit release

945.0 .. 5985A

Adjustment range short-term delayed short-circuit release

378.0 .. 6300A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Number of auxiliary contacts as normally open contact

0

Rated voltage

690 .. 690V

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Motor drive optional

With under voltage release

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.