Aleta.hr
Main Product Image

1SDA060209R1 | T6L 630 TMA 630-6300 4P F F

Code: 1527450

ManufacturerABB
Catalog number1SDA060209R1
EAN code8015644626679

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
With integrated under voltage releaseNo
Rated permanent current Iu630A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Overload release current setting441.0 - 630A
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Adjustment range undelayed short-circuit release3150 - 6300A
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
With switched-off indicatorNo
Motor drive integratedNo
Type of control elementToggle
Degree of protection (IP)IP20
Number of poles4
Motor drive optionalYes
Complete device with protection unitYes
Position of connection for main current circuitFront side
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA060209R1 | T6L 630 TMA 630-6300 4P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

With integrated under voltage release

Rated permanent current Iu

630A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Overload release current setting

441.0 .. 630A

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

3150 .. 6300A

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Motor drive integrated

Type of control element

Toggle

Degree of protection (IP)

IP20

Number of poles

4

Motor drive optional

Complete device with protection unit

Position of connection for main current circuit

Front side

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.