Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Overload release current setting252.0 - 630A
Type of control elementToggle
Degree of protection (IP)IP20
Number of poles4
Rated permanent current Iu630A
Rated voltage690 - 690V
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
With switched-off indicatorNo
Adjustment range undelayed short-circuit release1000 - 10000A
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalYes
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range short-term delayed short-circuit release1000 - 10000A
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA060231R1 | T6N 630 PR221DS-LS/I IN=630 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Overload release current setting

252.0 .. 630A

Type of control element

Toggle

Degree of protection (IP)

IP20

Number of poles

4

Rated permanent current Iu

630A

Rated voltage

690 .. 690V

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Adjustment range undelayed short-circuit release

1000 .. 10000A

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range short-term delayed short-circuit release

1000 .. 10000A

Device construction

Built-in device fixed built-in technique

With under voltage release

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.