Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting252.0 - 630A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu630A
Number of poles4
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitBolt connection
Rated voltage690 - 690V
Degree of protection (IP)IP20
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Motor drive integratedNo
Position of connection for main current circuitFront side
Type of control elementToggle
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release1000 - 10000A
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release1000 - 10000A
Complete device with protection unitYes
With switched-off indicatorNo
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA060263R1 | T6L 630 PR221DS-I IN=630 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

252.0 .. 630A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

630A

Number of poles

4

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Bolt connection

Rated voltage

690 .. 690V

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Motor drive integrated

Position of connection for main current circuit

Front side

Type of control element

Toggle

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

1000 .. 10000A

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

1000 .. 10000A

Complete device with protection unit

With switched-off indicator

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.