Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu800A
Number of auxiliary contacts as change-over contact0
Number of poles4
Overload release current setting320.0 - 800A
Position of connection for main current circuitFront side
Type of electrical connection of main circuitBolt connection
Degree of protection (IP)IP20
Rated voltage690 - 690V
Motor drive integratedNo
DIN rail (top hat rail) mounting optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Complete device with protection unitYes
Adjustment range undelayed short-circuit release1000 - 10000A
With under voltage releaseNo
With switched-off indicatorNo
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementToggle
Motor drive optionalYes
Adjustment range short-term delayed short-circuit release1000 - 10000A
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA060294R1 | T6H 800 PR221DS-LS/I IN=800 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

800A

Number of auxiliary contacts as change-over contact

0

Number of poles

4

Overload release current setting

320.0 .. 800A

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Bolt connection

Degree of protection (IP)

IP20

Rated voltage

690 .. 690V

Motor drive integrated

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Complete device with protection unit

Adjustment range undelayed short-circuit release

1000 .. 10000A

With under voltage release

With switched-off indicator

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Type of control element

Toggle

Motor drive optional

Adjustment range short-term delayed short-circuit release

1000 .. 10000A

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.