Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles3
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu800A
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP20
Overload release current setting320.0 - 800A
Rated voltage690 - 690V
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Type of control elementToggle
Adjustment range short-term delayed short-circuit release1000 - 10000A
Motor drive integratedNo
Type of electrical connection of main circuitBolt connection
With under voltage releaseNo
With switched-off indicatorNo
Complete device with protection unitYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Adjustment range undelayed short-circuit release1000 - 10000A
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA060300R1 | T6L 800 PR221DS-I IN=800 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

3

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

800A

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP20

Overload release current setting

320.0 .. 800A

Rated voltage

690 .. 690V

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Type of control element

Toggle

Adjustment range short-term delayed short-circuit release

1000 .. 10000A

Motor drive integrated

Type of electrical connection of main circuit

Bolt connection

With under voltage release

With switched-off indicator

Complete device with protection unit

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Adjustment range undelayed short-circuit release

1000 .. 10000A

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Motor drive optional

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.