Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of poles4
Rated permanent current Iu800A
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
Overload release current setting560.0 - 800A
Degree of protection (IP)IP20
With under voltage releaseNo
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Type of control elementToggle
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Complete device with protection unitYes
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release4000 - 8000A
Rated voltage1000 - 1000V
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA060317R1 | T6L 800 TMA 800-8000 4P F F 1000V AC/DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of poles

4

Rated permanent current Iu

800A

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

Overload release current setting

560.0 .. 800A

Degree of protection (IP)

IP20

With under voltage release

Motor drive optional

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Type of control element

Toggle

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Complete device with protection unit

Integrated earth fault protection

Adjustment range undelayed short-circuit release

4000 .. 8000A

Rated voltage

1000 .. 1000V

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.