Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Motor drive integratedNo
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Rated permanent current Iu1000A
DIN rail (top hat rail) mounting optionalNo
Overload release current setting400.0 - 1000A
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalYes
Rated voltage690 - 690V
Degree of protection (IP)IP20
Number of poles4
Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release1000 - 10000A
With under voltage releaseNo
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Type of control elementToggle
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release1000 - 10000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA060542R1 | T6N 1000 PR221DS-LS/I IN=1000 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Motor drive integrated

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Rated permanent current Iu

1000A

DIN rail (top hat rail) mounting optional

Overload release current setting

400.0 .. 1000A

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Rated voltage

690 .. 690V

Degree of protection (IP)

IP20

Number of poles

4

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

1000 .. 10000A

With under voltage release

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Type of control element

Toggle

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

1000 .. 10000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.