Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Rated permanent current Iu1000A
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Rated voltage690 - 690V
With integrated under voltage releaseNo
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
Overload release current setting400.0 - 1000A
Number of poles3
Motor drive optionalYes
Adjustment range short-term delayed short-circuit release1000 - 10000A
With switched-off indicatorNo
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Type of control elementToggle
Type of electrical connection of main circuitBolt connection
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release1000 - 10000A
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA060561R1 | T6H 1000 PR221DS-LS/I IN=1000 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

1000A

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Rated voltage

690 .. 690V

With integrated under voltage release

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

Overload release current setting

400.0 .. 1000A

Number of poles

3

Motor drive optional

Adjustment range short-term delayed short-circuit release

1000 .. 10000A

With switched-off indicator

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Type of control element

Toggle

Type of electrical connection of main circuit

Bolt connection

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

1000 .. 10000A

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.