  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
With under voltage releaseNo
Degree of protection (IP)IP20
Adjustment range short-term delayed short-circuit release480.0 - 8000A
DIN rail (top hat rail) mounting optionalNo
Adjustment range undelayed short-circuit release1200.0 - 12000A
Type of control elementToggle
Integrated earth fault protectionNo
Motor drive optionalNo
Rated voltage690 - 690V
Suitable for DIN rail (top hat rail) mountingNo
Motor drive integratedNo
Rated permanent current Iu800A
Device constructionBuilt-in device fixed built-in technique
Overload release current setting320.0 - 800A
With switched-off indicatorNo
Number of poles4
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Number of auxiliary contacts as change-over contact0
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA062686R1 | T7L 800 PR332/P LSI In=800A 4p F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

With under voltage release

Degree of protection (IP)

IP20

Adjustment range short-term delayed short-circuit release

480.0 .. 8000A

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Type of control element

Toggle

Integrated earth fault protection

Motor drive optional

Rated voltage

690 .. 690V

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

Rated permanent current Iu

800A

Device construction

Built-in device fixed built-in technique

Overload release current setting

320.0 .. 800A

With switched-off indicator

Number of poles

4

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Number of auxiliary contacts as change-over contact

0

Complete device with protection unit