Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage690 - 690V
Rated permanent current Iu800A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Number of poles3
Overload release current setting320.0 - 800A
Type of electrical connection of main circuitBolt connection
With switched-off indicatorNo
Type of control elementToggle
Degree of protection (IP)IP20
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalNo
Complete device with protection unitYes
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release480.0 - 8000A
Adjustment range undelayed short-circuit release1200.0 - 12000A
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
Motor drive integratedNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA062710R1 | T7V 800 PR332/P LSI In=800A 3p F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

690 .. 690V

Rated permanent current Iu

800A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Overload release current setting

320.0 .. 800A

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Type of control element

Toggle

Degree of protection (IP)

IP20

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Complete device with protection unit

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

480.0 .. 8000A

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Device construction

Built-in device fixed built-in technique

With under voltage release

Motor drive integrated

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.