Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles4
Rated permanent current Iu800A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated voltage690 - 690V
Type of electrical connection of main circuitBolt connection
Position of connection for main current circuitFront side
With switched-off indicatorNo
Degree of protection (IP)IP20
Integrated earth fault protectionNo
Overload release current setting320.0 - 800A
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Complete device with protection unitYes
Adjustment range undelayed short-circuit release1200.0 - 12000A
Motor drive optionalNo
DIN rail (top hat rail) mounting optionalNo
Type of control elementToggle
Adjustment range short-term delayed short-circuit release480.0 - 8000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA062718R1 | T7V 800 PR332/P LSI In=800A 4p F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

4

Rated permanent current Iu

800A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Bolt connection

Position of connection for main current circuit

Front side

With switched-off indicator

Degree of protection (IP)

IP20

Integrated earth fault protection

Overload release current setting

320.0 .. 800A

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Complete device with protection unit

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Motor drive optional

DIN rail (top hat rail) mounting optional

Type of control element

Toggle

Adjustment range short-term delayed short-circuit release

480.0 .. 8000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.