Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Rated permanent current Iu800A
Type of electrical connection of main circuitBolt connection
Adjustment range undelayed short-circuit release1200.0 - 12000A
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionNo
With under voltage releaseNo
With switched-off indicatorNo
Complete device with protection unitYes
Overload release current setting320.0 - 800A
Number of poles4
Motor drive integratedNo
Adjustment range short-term delayed short-circuit release480.0 - 8000A
Type of control elementToggle
Position of connection for main current circuitFront side
Motor drive optionalNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA062720R1 | T7V 800 PR332/P LSIRc In=800A 4p F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Rated permanent current Iu

800A

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

With under voltage release

With switched-off indicator

Complete device with protection unit

Overload release current setting

320.0 .. 800A

Number of poles

4

Motor drive integrated

Adjustment range short-term delayed short-circuit release

480.0 .. 8000A

Type of control element

Toggle

Position of connection for main current circuit

Front side

Motor drive optional

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.