Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Type of electrical connection of main circuitBolt connection
Rated permanent current Iu1000A
Overload release current setting400.0 - 1000A
Motor drive optionalNo
With switched-off indicatorNo
Motor drive integratedNo
Rated voltage690 - 690V
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release1500.0 - 15000A
Type of control elementToggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
With under voltage releaseNo
Integrated earth fault protectionNo
Number of poles4
Degree of protection (IP)IP20
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release600.0 - 10000A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA062752R1 | T7S 1000 PR332/P LSIRC IN=1000A 4P

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Bolt connection

Rated permanent current Iu

1000A

Overload release current setting

400.0 .. 1000A

Motor drive optional

With switched-off indicator

Motor drive integrated

Rated voltage

690 .. 690V

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Type of control element

Toggle

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

With under voltage release

Integrated earth fault protection

Number of poles

4

Degree of protection (IP)

IP20

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

600.0 .. 10000A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.