Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles4
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Rated voltage690 - 690V
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu1000A
Overload release current setting400.0 - 1000A
Number of auxiliary contacts as normally open contact0
Type of control elementPush button
Motor drive integratedNo
Position of connection for main current circuitFront side
Type of electrical connection of main circuitBolt connection
With switched-off indicatorNo
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release1000 - 10000A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release1000 - 10000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA062858R1 | T7V 1000 PR231/P LS/I IN=1000A 4P F F M

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

4

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Rated voltage

690 .. 690V

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

1000A

Overload release current setting

400.0 .. 1000A

Number of auxiliary contacts as normally open contact

0

Type of control element

Push button

Motor drive integrated

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Integrated earth fault protection

Adjustment range undelayed short-circuit release

1000 .. 10000A

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

1000 .. 10000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Device construction

Built-in device fixed built-in technique

Motor drive optional

DIN rail (top hat rail) mounting optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.