Aleta.hr
Main Product Image

1SDA062952R1 | T7L 1250 PR332/P LSIRC IN=1250A 3P

Code: 1528710

ManufacturerABB
Catalog number1SDA062952R1
EAN code8015644655013

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Rated voltage690 - 690V
Rated permanent current Iu1250A
Adjustment range undelayed short-circuit release1875.0 - 18750A
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Adjustment range short-term delayed short-circuit release750.0 - 12500A
Motor drive optionalYes
Number of poles3
Complete device with protection unitYes
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
Position of connection for main current circuitFront side
Overload release current setting500.0 - 1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Type of control elementPush button
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA062952R1 | T7L 1250 PR332/P LSIRC IN=1250A 3P

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated voltage

690 .. 690V

Rated permanent current Iu

1250A

Adjustment range undelayed short-circuit release

1875.0 .. 18750A

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Adjustment range short-term delayed short-circuit release

750.0 .. 12500A

Motor drive optional

Number of poles

3

Complete device with protection unit

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Position of connection for main current circuit

Front side

Overload release current setting

500.0 .. 1250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Type of control element

Push button

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.