Overload release current setting640.0 - 1600A
Number of poles4
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu1600A
DIN rail (top hat rail) mounting optionalNo
Adjustment range short-term delayed short-circuit release960.0 - 16000A
Type of control elementToggle
Adjustment range undelayed short-circuit release2400.0 - 24000A
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
With under voltage releaseNo
Motor drive integratedNo
Degree of protection (IP)IP20
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact0
Motor drive optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Position of connection for main current circuitFront side
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
Rated voltage690 - 690V
With switched-off indicatorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA063008R1 | T7S 1600 PR332/P LSIRC IN=1600A 4P

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

640.0 .. 1600A

Number of poles

4

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

1600A

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

960.0 .. 16000A

Type of control element

Toggle

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

With under voltage release

Motor drive integrated

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

0

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Position of connection for main current circuit

Front side

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

Rated voltage

690 .. 690V

With switched-off indicator