Aleta.hr
Main Product Image

1SDA063027R1 | T7H 1600 PR232/P LSI IN=1600A 3P F F

Code: 1528785

ManufacturerABB
Catalog number1SDA063027R1
EAN code8015644655761

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release2400.0 - 19200A
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu1600A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release960.0 - 16000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Overload release current setting640.0 - 1600A
Type of electrical connection of main circuitBolt connection
DIN rail (top hat rail) mounting optionalNo
Number of poles3
With switched-off indicatorNo
Position of connection for main current circuitFront side
Type of control elementToggle
Motor drive optionalNo
Degree of protection (IP)IP20
Motor drive integratedNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA063027R1 | T7H 1600 PR232/P LSI IN=1600A 3P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Integrated earth fault protection

Adjustment range undelayed short-circuit release

2400.0 .. 19200A

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

1600A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

960.0 .. 16000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Overload release current setting

640.0 .. 1600A

Type of electrical connection of main circuit

Bolt connection

DIN rail (top hat rail) mounting optional

Number of poles

3

With switched-off indicator

Position of connection for main current circuit

Front side

Type of control element

Toggle

Motor drive optional

Degree of protection (IP)

IP20

Motor drive integrated

Complete device with protection unit

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.