Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu1600A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
Rated voltage690 - 690V
Number of auxiliary contacts as change-over contact0
Overload release current setting640.0 - 1600A
Degree of protection (IP)IP20
Motor drive integratedNo
With switched-off indicatorNo
Position of connection for main current circuitFront side
Number of poles3
Type of control elementToggle
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release1600 - 16000A
Adjustment range undelayed short-circuit release1600 - 16000A
With under voltage releaseNo
Motor drive optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA063058R1 | T7L 1600 PR231/P LS/I IN=1600A 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

1600A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

Rated voltage

690 .. 690V

Number of auxiliary contacts as change-over contact

0

Overload release current setting

640.0 .. 1600A

Degree of protection (IP)

IP20

Motor drive integrated

With switched-off indicator

Position of connection for main current circuit

Front side

Number of poles

3

Type of control element

Toggle

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

1600 .. 16000A

Adjustment range undelayed short-circuit release

1600 .. 16000A

With under voltage release

Motor drive optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.