1SDA063074R1 | T7L 1600 PR231/P LS/I IN=1600A 3P F F M

Code: 1528832

ManufacturerABB
Catalog number1SDA063074R1
EAN code8015644656232

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Overload release current setting640.0 - 1600A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitBolt connection
Number of poles3
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release1600 - 16000A
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
Rated permanent current Iu1600A
With under voltage releaseNo
Position of connection for main current circuitFront side
With switched-off indicatorNo
Type of control elementPush button
Motor drive optionalYes
Adjustment range undelayed short-circuit release1600 - 16000A
Degree of protection (IP)IP20
Motor drive integratedNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA063074R1 | T7L 1600 PR231/P LS/I IN=1600A 3P F F M

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Overload release current setting

640.0 .. 1600A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Bolt connection

Number of poles

3

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

1600 .. 16000A

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Rated permanent current Iu

1600A

With under voltage release

Position of connection for main current circuit

Front side

With switched-off indicator

Type of control element

Push button

Motor drive optional

Adjustment range undelayed short-circuit release

1600 .. 16000A

Degree of protection (IP)

IP20

Motor drive integrated