Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu2500A
Number of auxiliary contacts as normally open contact0
Number of poles4
Overload release current setting- - -A
Motor drive optionalNo
Degree of protection (IP)IP20
With under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Adjustment range short-term delayed short-circuit release- - -A
With switched-off indicatorNo
Type of electrical connection of main circuitBolt connection
DIN rail (top hat rail) mounting optionalNo
Adjustment range undelayed short-circuit release- - -A
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingNo
Rated voltage690 - 690V
Device constructionBuilt-in device fixed built-in technique
Motor drive integratedNo
Integrated earth fault protectionYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA065765R1 | T8L 2500 PR331/P LSIG In=2500 4p F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

2500A

Number of auxiliary contacts as normally open contact

0

Number of poles

4

Overload release current setting

- .. -A

Motor drive optional

Degree of protection (IP)

IP20

With under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Adjustment range short-term delayed short-circuit release

- .. -A

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

- .. -A

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

Rated voltage

690 .. 690V

Device construction

Built-in device fixed built-in technique

Motor drive integrated

Integrated earth fault protection

Complete device with protection unit