Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu160A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Motor drive integratedNo
Type of electrical connection of main circuitBolt connection
Rated voltage220 - 690V
Degree of protection (IP)IP20
Number of poles3
Number of auxiliary contacts as change-over contact0
Type of control elementToggle
Overload release current setting35.0 - 50A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release- - -A
Adjustment range undelayed short-circuit release500 - 500A
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz18kA
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA066804R1 | XT1B 160 TMD 50-500 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

160A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Motor drive integrated

Type of electrical connection of main circuit

Bolt connection

Rated voltage

220 .. 690V

Degree of protection (IP)

IP20

Number of poles

3

Number of auxiliary contacts as change-over contact

0

Type of control element

Toggle

Overload release current setting

35.0 .. 50A

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

- .. -A

Adjustment range undelayed short-circuit release

500 .. 500A

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

18kA

Device construction

Built-in device fixed built-in technique

With under voltage release

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Motor drive optional

Complete device with protection unit