Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of poles3
Overload release current setting112.0 - 160A
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Rated voltage220 - 690V
Type of control elementToggle
Motor drive integratedNo
Motor drive optionalYes
Adjustment range undelayed short-circuit release1600 - 1600A
With switched-off indicatorNo
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionNo
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release- - -A
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz18kA
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA066809R1 | XT1B 160 TMD 160-1600 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

Overload release current setting

112.0 .. 160A

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Rated voltage

220 .. 690V

Type of control element

Toggle

Motor drive integrated

Motor drive optional

Adjustment range undelayed short-circuit release

1600 .. 1600A

With switched-off indicator

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

- .. -A

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

18kA

With under voltage release

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.