Aleta.hr
Main Product Image

1SDA066818R1 | XT1B 160 TMD 100-1000 4P F F

Code: 1529487

ManufacturerABB
Catalog number1SDA066818R1
EAN code8015644007256

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
DIN rail (top hat rail) mounting optionalYes
Adjustment range undelayed short-circuit release1000 - 1000A
Type of control elementToggle
Complete device with protection unitYes
Integrated earth fault protectionNo
Overload release current setting70.0 - 100A
Position of connection for main current circuitFront side
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Number of poles4
Rated voltage220 - 690V
Type of electrical connection of main circuitBolt connection
With under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz18kA
With switched-off indicatorNo
Motor drive optionalYes
Motor drive integratedNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA066818R1 | XT1B 160 TMD 100-1000 4P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

1000 .. 1000A

Type of control element

Toggle

Complete device with protection unit

Integrated earth fault protection

Overload release current setting

70.0 .. 100A

Position of connection for main current circuit

Front side

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Number of poles

4

Rated voltage

220 .. 690V

Type of electrical connection of main circuit

Bolt connection

With under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

18kA

With switched-off indicator

Motor drive optional

Motor drive integrated

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.