Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu160A
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally open contact0
Integrated earth fault protectionNo
Motor drive integratedNo
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Type of control elementToggle
Adjustment range short-term delayed short-circuit release- - -A
Degree of protection (IP)IP20
Rated voltage220 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range undelayed short-circuit release300 - 300A
Overload release current setting14.0 - 20A
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
Number of poles3
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067011R1 | XT2N 160 TMD 20-300 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

160A

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally open contact

0

Integrated earth fault protection

Motor drive integrated

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Type of control element

Toggle

Adjustment range short-term delayed short-circuit release

- .. -A

Degree of protection (IP)

IP20

Rated voltage

220 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range undelayed short-circuit release

300 .. 300A

Overload release current setting

14.0 .. 20A

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

Motor drive optional

DIN rail (top hat rail) mounting optional

With under voltage release

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.