Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
Number of poles4
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
Type of control elementToggle
Motor drive integratedNo
Rated permanent current Iu160A
With under voltage releaseNo
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release300 - 300A
With switched-off indicatorNo
Rated voltage220 - 690V
Motor drive optionalYes
Overload release current setting17.5 - 25A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range short-term delayed short-circuit release- - -A
Suitable for DIN rail (top hat rail) mountingNo
Position of connection for main current circuitFront side
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067033R1 | XT2N 160 TMD 25-300 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

Number of poles

4

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

Type of control element

Toggle

Motor drive integrated

Rated permanent current Iu

160A

With under voltage release

Integrated earth fault protection

Adjustment range undelayed short-circuit release

300 .. 300A

With switched-off indicator

Rated voltage

220 .. 690V

Motor drive optional

Overload release current setting

17.5 .. 25A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range short-term delayed short-circuit release

- .. -A

Suitable for DIN rail (top hat rail) mounting

Position of connection for main current circuit

Front side

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.