1SDA067043R1 | XT2N 160 TMA 160-1600 4P F F INN=100%

Code: 1529689

ManufacturerABB
Catalog number1SDA067043R1
EAN code8015644009496

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated voltage220 - 690V
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Overload release current setting112.0 - 160A
Type of electrical connection of main circuitBolt connection
Adjustment range undelayed short-circuit release800 - 1600A
Integrated earth fault protectionNo
With switched-off indicatorNo
With under voltage releaseNo
Position of connection for main current circuitFront side
Rated permanent current Iu160A
Type of control elementToggle
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
Degree of protection (IP)IP20
Number of poles4
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067043R1 | XT2N 160 TMA 160-1600 4P F F INN=100%

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated voltage

220 .. 690V

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Overload release current setting

112.0 .. 160A

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

800 .. 1600A

Integrated earth fault protection

With switched-off indicator

With under voltage release

Position of connection for main current circuit

Front side

Rated permanent current Iu

160A

Type of control element

Toggle

Complete device with protection unit

Motor drive integrated

Motor drive optional

DIN rail (top hat rail) mounting optional

Degree of protection (IP)

IP20

Number of poles

4

Device construction

Built-in device fixed built-in technique

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.