1SDA067056R1 | XT2N 160 EKIP LS/I IN=63A 3P F F

Code: 1529702

ManufacturerABB
Catalog number1SDA067056R1
EAN code8015644007935

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
Rated voltage220 - 690V
Number of poles3
Adjustment range undelayed short-circuit release63 - 630A
Adjustment range short-term delayed short-circuit release63 - 630A
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Type of control elementToggle
With under voltage releaseNo
With switched-off indicatorNo
Overload release current setting25.2 - 63A
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Complete device with protection unitYes

Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067056R1 | XT2N 160 EKIP LS/I IN=63A 3P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

Rated voltage

220 .. 690V

Number of poles

3

Adjustment range undelayed short-circuit release

63 .. 630A

Adjustment range short-term delayed short-circuit release

63 .. 630A

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Type of control element

Toggle

With under voltage release

With switched-off indicator

Overload release current setting

25.2 .. 63A

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Motor drive optional

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Complete device with protection unit

From same serie

Recommended products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.