Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Overload release current setting- - -A
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release- - -A
Rated permanent current Iu160A
Type of electrical connection of main circuitBolt connection
Adjustment range undelayed short-circuit release192 - 448A
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
With switched-off indicatorNo
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
Complete device with protection unitYes
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Rated voltage220 - 690V
Position of connection for main current circuitFront side
Number of poles3
Degree of protection (IP)IP20
Type of control elementToggle
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067087R1 | XT2N 160 EKIP M-I IN=32A 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

- .. -A

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

- .. -A

Rated permanent current Iu

160A

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

192 .. 448A

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

With switched-off indicator

Device construction

Built-in device fixed built-in technique

Motor drive optional

Complete device with protection unit

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Rated voltage

220 .. 690V

Position of connection for main current circuit

Front side

Number of poles

3

Degree of protection (IP)

IP20

Type of control element

Toggle

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.