Technical specifications

Number of auxiliary contacts as normally open contact0
Number of poles4
Number of auxiliary contacts as change-over contact0
Rated voltage220 - 690V
Rated permanent current Iu160A
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP20
Motor drive integratedNo
Adjustment range short-term delayed short-circuit release25 - 250A
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Position of connection for main current circuitFront side
Type of control elementToggle
Type of electrical connection of main circuitBolt connection
Overload release current setting10.0 - 25A
Motor drive optionalYes
Adjustment range undelayed short-circuit release25 - 250A
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067091R1 | XT2N 160 EKIP LS/I IN=25A 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of poles

4

Number of auxiliary contacts as change-over contact

0

Rated voltage

220 .. 690V

Rated permanent current Iu

160A

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP20

Motor drive integrated

Adjustment range short-term delayed short-circuit release

25 .. 250A

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Position of connection for main current circuit

Front side

Type of control element

Toggle

Type of electrical connection of main circuit

Bolt connection

Overload release current setting

10.0 .. 25A

Motor drive optional

Adjustment range undelayed short-circuit release

25 .. 250A

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

DIN rail (top hat rail) mounting optional