Technical specifications

Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Number of auxiliary contacts as normally closed contact0
Rated voltage220 - 690V
Number of poles4
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release10 - 100A
Suitable for DIN rail (top hat rail) mountingNo
Motor drive integratedNo
Type of electrical connection of main circuitBolt connection
Motor drive optionalYes
Overload release current setting4.0 - 10A
Adjustment range undelayed short-circuit release10 - 100A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
With under voltage releaseNo
Type of control elementToggle
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067102R1 | XT2N 160 EKIP LSI IN=10A 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Number of auxiliary contacts as normally closed contact

0

Rated voltage

220 .. 690V

Number of poles

4

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

With switched-off indicator

Adjustment range short-term delayed short-circuit release

10 .. 100A

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

Type of electrical connection of main circuit

Bolt connection

Motor drive optional

Overload release current setting

4.0 .. 10A

Adjustment range undelayed short-circuit release

10 .. 100A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Position of connection for main current circuit

Front side

Integrated earth fault protection

With under voltage release

Type of control element

Toggle

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Complete device with protection unit