Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

DIN rail (top hat rail) mounting optionalYes
Adjustment range short-term delayed short-circuit release100 - 1000A
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Motor drive optionalYes
Rated voltage220 - 690V
Degree of protection (IP)IP20
Type of control elementToggle
Number of auxiliary contacts as change-over contact0
Complete device with protection unitYes
With under voltage releaseNo
Rated permanent current Iu160A
Position of connection for main current circuitFront side
Overload release current setting40.0 - 100A
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release100 - 1000A
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionYes
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Motor drive integratedNo
Number of poles4
Number of auxiliary contacts as normally open contact0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067111R1 | XT2N 160 EKIP LSIG IN=100A 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

100 .. 1000A

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Motor drive optional

Rated voltage

220 .. 690V

Degree of protection (IP)

IP20

Type of control element

Toggle

Number of auxiliary contacts as change-over contact

0

Complete device with protection unit

With under voltage release

Rated permanent current Iu

160A

Position of connection for main current circuit

Front side

Overload release current setting

40.0 .. 100A

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

100 .. 1000A

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

Number of poles

4

Number of auxiliary contacts as normally open contact

0

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.