Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Number of poles4
Rated voltage220 - 690V
Number of auxiliary contacts as change-over contact0
Overload release current setting22.4 - 32A
Motor drive integratedNo
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
With switched-off indicatorNo
Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release- - -A
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Type of control elementToggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalYes
Complete device with protection unitYes
With under voltage releaseNo
Adjustment range undelayed short-circuit release450 - 450A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067401R1 | XT1C 160 TMD 32-450 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Number of poles

4

Rated voltage

220 .. 690V

Number of auxiliary contacts as change-over contact

0

Overload release current setting

22.4 .. 32A

Motor drive integrated

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

- .. -A

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Type of control element

Toggle

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Complete device with protection unit

With under voltage release

Adjustment range undelayed short-circuit release

450 .. 450A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.