Number of poles3
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Overload release current setting22.4 - 32A
Rated permanent current Iu160A
Position of connection for main current circuitFront side
Rated voltage220 - 690V
Type of control elementToggle
Integrated earth fault protectionNo
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release450 - 450A
Motor drive optionalYes
Degree of protection (IP)IP20
Motor drive integratedNo
With under voltage releaseNo
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release- - -A
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
With switched-off indicatorNo
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique

Recommended products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067411R1 | XT1N 160 TMD 32-450 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Overload release current setting

22.4 .. 32A

Rated permanent current Iu

160A

Position of connection for main current circuit

Front side

Rated voltage

220 .. 690V

Type of control element

Toggle

Integrated earth fault protection

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

450 .. 450A

Motor drive optional

Degree of protection (IP)

IP20

Motor drive integrated

With under voltage release

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

- .. -A

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

Recommended products