  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu160A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of poles3
Overload release current setting35.0 - 50A
Rated voltage220 - 690V
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Type of control elementToggle
Adjustment range short-term delayed short-circuit release- - -A
With switched-off indicatorNo
Adjustment range undelayed short-circuit release500 - 500A
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Motor drive integratedNo
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067449R1 | XT1H 160 TMD 50-500 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

160A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Overload release current setting

35.0 .. 50A

Rated voltage

220 .. 690V

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Type of control element

Toggle

Adjustment range short-term delayed short-circuit release

- .. -A

With switched-off indicator

Adjustment range undelayed short-circuit release

500 .. 500A

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Motor drive optional

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

With under voltage release