  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Position of connection for main current circuitFront side
Rated voltage220 - 690V
Number of auxiliary contacts as normally closed contact0
Overload release current setting44.1 - 63A
Degree of protection (IP)IP20
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Number of auxiliary contacts as change-over contact0
Number of poles3
Type of electrical connection of main circuitBolt connection
Type of control elementToggle
Adjustment range short-term delayed short-circuit release- - -A
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Adjustment range undelayed short-circuit release630 - 630A
Motor drive integratedNo
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
Motor drive optionalYes
With under voltage releaseNo
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067450R1 | XT1H 160 TMD 63-630 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Position of connection for main current circuit

Front side

Rated voltage

220 .. 690V

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

44.1 .. 63A

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Type of electrical connection of main circuit

Bolt connection

Type of control element

Toggle

Adjustment range short-term delayed short-circuit release

- .. -A

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Adjustment range undelayed short-circuit release

630 .. 630A

Motor drive integrated

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

Motor drive optional

With under voltage release

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.