  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage220 - 690V
Degree of protection (IP)IP20
Overload release current setting1.4 - 2A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
Position of connection for main current circuitFront side
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Suitable for DIN rail (top hat rail) mountingNo
Motor drive integratedNo
Type of control elementToggle
Adjustment range undelayed short-circuit release20 - 20A
Adjustment range short-term delayed short-circuit release- - -A
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
With switched-off indicatorNo
Complete device with protection unitYes
Number of poles3
Integrated earth fault protectionNo
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067541R1 | XT2S 160 TMD 2-20 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

220 .. 690V

Degree of protection (IP)

IP20

Overload release current setting

1.4 .. 2A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

Type of control element

Toggle

Adjustment range undelayed short-circuit release

20 .. 20A

Adjustment range short-term delayed short-circuit release

- .. -A

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

With under voltage release

With switched-off indicator

Complete device with protection unit

Number of poles

3

Integrated earth fault protection

Motor drive optional