Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles3
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
Rated voltage220 - 690V
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitBolt connection
Overload release current setting1.75 - 2.5A
Motor drive integratedNo
Type of control elementToggle
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release25.0 - 25.0A
Motor drive optionalYes
Adjustment range short-term delayed short-circuit release- - -A
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067542R1 | XT2S 160 TMD 2,5-25 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

3

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

Rated voltage

220 .. 690V

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Bolt connection

Overload release current setting

1.75 .. 2.5A

Motor drive integrated

Type of control element

Toggle

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

25.0 .. 25.0A

Motor drive optional

Adjustment range short-term delayed short-circuit release

- .. -A

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Position of connection for main current circuit

Front side

Integrated earth fault protection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.