Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu160A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitBolt connection
With switched-off indicatorNo
Overload release current setting3.5 - 5A
Position of connection for main current circuitFront side
Rated voltage220 - 690V
Type of control elementToggle
Motor drive integratedNo
Degree of protection (IP)IP20
Number of poles3
Adjustment range short-term delayed short-circuit release- - -A
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release50 - 50A
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067545R1 | XT2S 160 TMD 5-50 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

160A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Overload release current setting

3.5 .. 5A

Position of connection for main current circuit

Front side

Rated voltage

220 .. 690V

Type of control element

Toggle

Motor drive integrated

Degree of protection (IP)

IP20

Number of poles

3

Adjustment range short-term delayed short-circuit release

- .. -A

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Motor drive optional

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Adjustment range undelayed short-circuit release

50 .. 50A

With under voltage release

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.