Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of electrical connection of main circuitBolt connection
With under voltage releaseNo
Rated permanent current Iu160A
Motor drive integratedNo
Adjustment range undelayed short-circuit release80 - 80A
Position of connection for main current circuitFront side
With switched-off indicatorNo
Rated voltage220 - 690V
Integrated earth fault protectionNo
Motor drive optionalYes
Degree of protection (IP)IP20
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Overload release current setting5.6 - 8A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release- - -A
Number of poles4
Number of auxiliary contacts as change-over contact0
Type of control elementToggle
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067568R1 | XT2S 160 TMD 8-80 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of electrical connection of main circuit

Bolt connection

With under voltage release

Rated permanent current Iu

160A

Motor drive integrated

Adjustment range undelayed short-circuit release

80 .. 80A

Position of connection for main current circuit

Front side

With switched-off indicator

Rated voltage

220 .. 690V

Integrated earth fault protection

Motor drive optional

Degree of protection (IP)

IP20

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Overload release current setting

5.6 .. 8A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

- .. -A

Number of poles

4

Number of auxiliary contacts as change-over contact

0

Type of control element

Toggle

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.