Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated voltage220 - 690V
With switched-off indicatorNo
Number of poles4
Type of electrical connection of main circuitBolt connection
Overload release current setting22.4 - 32A
Rated permanent current Iu160A
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Degree of protection (IP)IP20
Adjustment range short-term delayed short-circuit release- - -A
Motor drive integratedNo
Type of control elementToggle
Number of auxiliary contacts as change-over contact0
Motor drive optionalYes
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Adjustment range undelayed short-circuit release320 - 320A
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067574R1 | XT2S 160 TMD 32-320 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated voltage

220 .. 690V

With switched-off indicator

Number of poles

4

Type of electrical connection of main circuit

Bolt connection

Overload release current setting

22.4 .. 32A

Rated permanent current Iu

160A

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Degree of protection (IP)

IP20

Adjustment range short-term delayed short-circuit release

- .. -A

Motor drive integrated

Type of control element

Toggle

Number of auxiliary contacts as change-over contact

0

Motor drive optional

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

320 .. 320A

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

With under voltage release