Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Rated voltage220 - 690V
Number of poles3
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
Overload release current setting4.41 - 6.3A
Rated permanent current Iu160A
Position of connection for main current circuitFront side
Adjustment range short-term delayed short-circuit release- - -A
Motor drive integratedNo
With switched-off indicatorNo
Type of electrical connection of main circuitBolt connection
Type of control elementToggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release63.0 - 63.0A
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
Integrated earth fault protectionNo
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067590R1 | XT2H 160 TMD 6,3-63 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Rated voltage

220 .. 690V

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

Overload release current setting

4.41 .. 6.3A

Rated permanent current Iu

160A

Position of connection for main current circuit

Front side

Adjustment range short-term delayed short-circuit release

- .. -A

Motor drive integrated

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

Type of control element

Toggle

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

63.0 .. 63.0A

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Integrated earth fault protection

Motor drive optional

DIN rail (top hat rail) mounting optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.