Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
Rated voltage220 - 690V
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Overload release current setting4.41 - 6.3A
With switched-off indicatorNo
Number of poles3
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
Adjustment range undelayed short-circuit release63.0 - 63.0A
Complete device with protection unitYes
Type of control elementToggle
Motor drive optionalYes
Motor drive integratedNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067590R1 | XT2H 160 TMD 6,3-63 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

Rated voltage

220 .. 690V

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Overload release current setting

4.41 .. 6.3A

With switched-off indicator

Number of poles

3

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

With under voltage release

Adjustment range undelayed short-circuit release

63.0 .. 63.0A

Complete device with protection unit

Type of control element

Toggle

Motor drive optional

Motor drive integrated

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.