Technical specifications

Number of poles3
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu160A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Overload release current setting5.6 - 8A
Rated voltage220 - 690V
Type of control elementToggle
Position of connection for main current circuitFront side
Adjustment range short-term delayed short-circuit release- - -A
With switched-off indicatorNo
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release80 - 80A
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalYes
Motor drive integratedNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067591R1 | XT2H 160 TMD 8-80 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

160A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Overload release current setting

5.6 .. 8A

Rated voltage

220 .. 690V

Type of control element

Toggle

Position of connection for main current circuit

Front side

Adjustment range short-term delayed short-circuit release

- .. -A

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

With under voltage release

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

80 .. 80A

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Motor drive optional

Motor drive integrated

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.