Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Overload release current setting7.0 - 10A
Number of poles3
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Rated voltage220 - 690V
Rated permanent current Iu160A
Position of connection for main current circuitFront side
Complete device with protection unitYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Integrated earth fault protectionNo
With under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Adjustment range short-term delayed short-circuit release- - -A
Type of electrical connection of main circuitBolt connection
Motor drive optionalYes
Type of control elementToggle
Motor drive integratedNo
With switched-off indicatorNo
Adjustment range undelayed short-circuit release100 - 100A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067592R1 | XT2H 160 TMD 10-100 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Overload release current setting

7.0 .. 10A

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Rated voltage

220 .. 690V

Rated permanent current Iu

160A

Position of connection for main current circuit

Front side

Complete device with protection unit

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Integrated earth fault protection

With under voltage release

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

- .. -A

Type of electrical connection of main circuit

Bolt connection

Motor drive optional

Type of control element

Toggle

Motor drive integrated

With switched-off indicator

Adjustment range undelayed short-circuit release

100 .. 100A