Technical specifications

Rated permanent current Iu160A
With switched-off indicatorNo
Rated voltage220 - 690V
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
Adjustment range undelayed short-circuit release320 - 320A
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitBolt connection
Overload release current setting22.4 - 32A
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
Number of poles3
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Number of auxiliary contacts as normally closed contact0
Adjustment range short-term delayed short-circuit release- - -A
Type of control elementToggle
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
Complete device with protection unitYes
With under voltage releaseNo
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067597R1 | XT2H 160 TMD 32-320 3P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

160A

With switched-off indicator

Rated voltage

220 .. 690V

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

Adjustment range undelayed short-circuit release

320 .. 320A

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Bolt connection

Overload release current setting

22.4 .. 32A

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Number of auxiliary contacts as normally closed contact

0

Adjustment range short-term delayed short-circuit release

- .. -A

Type of control element

Toggle

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Complete device with protection unit

With under voltage release

Motor drive optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.